logo
  Shopping Cart: 0 items Total: $0.00
   Top » Fire Retardants » Burn Barrier™ 10-10


Acoustical Baffles >>
Acoustical Foam Tiles >>
Adhesives- Acoustical Sealants
Adjustable Cutter - Quick Cutter - Sprinkler Cutter
Adjustable Door Seals
Bass Buster
Composite Acoustical Panels
dBA Panels
Echo Eliminator
Green Glue
Home Thearter Acoustical Kits
KikBrik Drum Damper
Mass Loaded Vinyl Barrier
Noise Reduction Headphones
Quiet Light - Talk Light
RSIC-1 Clips
Sound Absorbing Foam
Sound Level Meters
Sound Silencer
Soundproof Floors
SQUARELINE Acoustical Metal Tiles
Stud/Beam Isolators
UltraTouch Insulation Knife
Vibration Mounts - Hangers & Pads
Wall Insulation
White Noise Machine
Fire Retardants



Guilford Color Charts

Burn Barrier™ 10-10
[BB10-10]
$103.50
Quantity Per Pack: 1
Unit Price: $103.50
Available Downloads:
MSDS Burn Barrier™ 10-10

Color Options

Product Description:
BURN BARRIER™ – 10-10 is a solvent based intumescent fire retardant paint and is
manufactured in accordance with Federal Specification TT-P-26C. It is designed for use on
interior surfaces. The coating dries quickly to a velvety flat finish, having the appearance of
a conventional paint. Upon exposure to fire, BURN BARRIER™ – 10-10 puffs up (intumesces),
forming a dense cellular foam layer. This foam layer greatly reduces the surface
burning characteristics of combustible materials, and retards the penetration of heat to
metal surfaces.

Surface Preparation:
Surface preparation should be carried out according to good painting practices. All dirt,
grease, oil, wax, rust and other foreign matter must be removed.

New Surfaces:
New wood, fiberboard and other surfaces having uneven or excessive porosity should be
sealed with No. 3001 Alkyd Primer, and allowed to dry a minimum of 16 hours before
applying BURN BARRIER™ 10-10. New drywall, plaster and masonry surfaces should be
internally dry and cured. Prime with No. 3003 Acrylic Primer, and allow to dry overnight
before applying BURN BARRIER™ 10-10. New metal surfaces must be primed. Apply No.
3004 Universal Primer or No. 3005 Two Component Epoxy Primer. Allow to dry 16 hours
or until hard, before applying BURN BARRIER™ 10-10.

Previously Painted Surfaces:
BURN BARRIER™ 10-10 may be applied directly to existing paint that is tightly adherent
and in good condition.All glossy surfaces should be dulled with sandpaper. Spot prime
where necessary with appropriate primers as shown above, before application of BURN
BARRIER™ 10-10.

Application:
BURN BARRIER™ 10-10 is ready to use. It can be applied by brush, roller, airless or
conventional heavy duty spray equipment. Stir thoroughly and apply, using a full bodied
coat. If thinning is required, use only BURN BARRIER™ 10-10 Reducer. Do not apply in
temperatures below 50°F (100 C).
Suggested Coverage Rate: 190 to 230 sq.ft./US gallon (230 to 275 sq.ft./Imp. gal) in one
or two coats. See fire hazard classification for specific coverage rates.

Drying Time:
Dries to touch in approximately 4 hours. Allow at least 24 hours drying time before over
coating.

Thinners:
For thinning use BURN BARRIER™ 10-10 Reducer, and when cleaning use Rule 66
mineral spirits.

Fire Tests:
Flame Spread Rating: Class “A”. When tested in accordance with ASTM E-84 (NFPA 255) the
coating obtained the following fire hazard classifications. A complete Underwriters’ Laboratory
report is available upon request.

FIRE HAZARD CLASSIFICATION:

Surface Douglas Fir Douglas Fir
Flame Spread Rating 15 15
Fuel Contributed 15 15
Smoke Developed 15 15
Number of preliminary coats None None
Number of Fire Retardant coats 1 1
Rate per coat:
sq.ft./gal. U.S. (Imp) 230 (275) 190 (230)
Number of Overcoats None *1
sq.ft./gal. U.S. (Imp) 615 (750)

*Overcoated with No. 40-40 Low Gloss Fire Retardant Coating.

Tinting:
Available in white, off-white, and pastel shades, or may be field tinted with most universal
or oil tinting colorants. Tinting colorants should not exceed 2 fluid ounces per gallon.

Packaging:
Standard packaging, 1 gallon, 5 gallon and 55 gallon containers.

PRECAUTIONS:
CAUTION! COMBUSTIBLE. Keep away from heat and open flame. Avoid prolonged
contact with skin and breathing of vapor or spray mist. Do not take internally. Close
container after each use. Use only with adequate ventilation. KEEP OUT OF REACH OF CHILDREN. Protect from freezing.

NOTE: All porous surfaces should be properly sealed before applying fire retardant paint or
varnish.

CAUTION: It is recommended that a test application be completed prior to end use.
Information provided herein is based on tests believed to be reliable. Inasmuch as Fire
Retardants inc. has no control over the use or application to which others may put this
material, we make no guarantee or warranty. Our products are sold on the condition that each
user of the material make their own evaluation to determine the material's suitability for their
own particular use.

© Fire Retardants Inc. All Rights Reserved.© Fire Retardants Inc. All Rights Reserved

Note: This Product will ship within 48 hours if UPS ground is Selected.

Note: This Product will ship within 24 hours if UPS Next day, 2 day or 3 day is Selected.

Available Options:
Color Options:
For more information, please visit this products webpage.
 
Currencies
My Account
Please Log In
Username:
Password:
Create Account
Shopping Cart
0 items
RFQ Cart
0 items
Quick Find


Use keywords to find the product you are looking for.

Advanced Search
Information
Shipping & Returns
Contact Us
Tell A Friend
 

Tell someone you know about this product.
Phone: 952.448.5300 - Fax: 952.448.2613 - Email: sales@buyacoustics.com